Acuvim II Power Meter,
Internet Connection.
Emails current-alarm conditions. Time
intervals and Alarms using the
optional TCP/IP browser protocol.
FREE Data logging software
Demo.
In a few minutes
your computer will be in communication with a Acuvim II meter
located in Toronto. The meter could be in place at your facility...
Installations Instructions- Demo Acuview software.
Demo Download of Acuview software.
Acuview Software users guide.
Acuvim
Communication Hookup Drawings.
|
The Acuvim II, inexpensive high-end
multifunction power meter with multiple communication
schemes and RS485 Comm. ports standard Optional
modules for: I/O, digital and analog, Profibus-DP,
Ethernet, Web based Email.
Acuvim II Users Manual.
Modbus Map.
Ethernet Module Data.
|
Highly economical
choice for monitoring and controlling power distribution
systems.
| Model |
Input |
Supply |
Price |
| Acuvim-II |
5 Amp Input |
AC/DC |
$ 495.00 |
| Acuvim-II |
5 Amp Input |
24VDC |
$ 570.00 |
| Acuvim-II |
1 Amp Input |
AC/DC |
$ 525.00 |
| Acuvim-IIR |
5 Amp Input |
AC/DC |
$ 695.00 |
Optional I/O and
communication modules are listed below. Meter supports 3ea.
I/O modules.
Need Revenue Grade devices?
|
Acuvim II Brochure
|
Features:
 |
Software |
 |
Acuview Data logging software ships with every meter.
|
 | Metering
 | Voltage, Current, Power, Reactive Power, Apparent
Power, |
 | Frequency, Power Factor, Energy, Reactive Energy,
Demand |
|
 | Monitoring
 | Power Quality: |
 | Voltage Harmonics 2nd to 31st and THD |
 | Current Harmonics 2nd to 31st and THD |
 | Voltage Crest Factor |
 | THFF (TIF) |
 | Current K Factor |
 | Voltage Unbalance Factor U_unbl |
 | Current Unbalance Factor U_unbl |
 | Max/Min Statistics with Time Stamps |
 | Switch Status |
|
 | Remote Control
 | Alarms
|
 | The over/under limits of the less than 9 indicated
parameters |
|
 | Ethernet or Profibus Communication
 | 10M/100M self-adaptable, RJ45 Jack Modbus-TCP/IP
Protocol |
 | HTTP Web page browse Email sending on time interval
or on event |
 | Profibus-DP/V0 Input Byte (typical): 32 byte Output
Byte (typical): vol.2 compliance |
 | Profibus slave mode, baud rate self-adaptable up to
12M |
|
 | Flexible I/O module
 | Digital In, Digital Out, Relay Out, Analog
In, Analog Out, Pulse |
|
 | 2 Communication Ports |
|
| Function |
|
Parameter |
|
Phase Voltage |
V1, 2, 3 |
| REAL TIME |
Line Voltage |
V1-2, 2-3, 3-1 |
| METERING |
Current |
I1, 2, 3,L-N |
|
Power
(KW Instant) |
P1, 2, 3, sum |
|
Reactive Power |
Q1, 2, 3, sum |
|
Apparent Power |
Ssum |
|
Power Factor |
PF1, F2, F3, F |
|
ENERGY
(KWh) |
Ep_iimp, p_exp, |
|
REACTIVE ENERGY |
Eq_imp, q_exp |
| ENERGY DEMAND |
Apparent Energy |
Dmd_I1,DDmd_I2 md_II3 |
|
POWER DEMAND |
Dmd_Psum, md_QQsum |
|
Voltage Imbalance Factor |
V_unbl |
|
Current Imbalance |
I_unbl |
| POWER QUALITY |
Voltage THD |
THD_V1, THD_V2, THD_V3, |
|
Current THD |
THD_I1, THD_I2, THD_I3 |
|
Individual Harmonics |
2 nd 31 th (Current and Voltage) |
|
Voltage Crest Facctor |
Crest Factor |
|
TIF |
THFF |
|
Current K Factor |
K Factor |
| STATISTICS |
Max with Time Stamp |
|
|
Min with Time Stamp |
|
| ALARM |
Over Under Limit Alarm |
|
| COMMUNICATION |
RS-4485 MODBUS ®-RTU Protocol |
| TIME |
Real Time Clock |
|
|
Switch Status (DI) |
Digital input wet |
|
Power Supply for DI |
24VDC |
|
Relay Output (RO) |
NO, Form A |
| I/O OPTIONAL |
Digital Output (DO) |
Photo -MOS |
| MODULES |
Pulse Output (PO) |
By using DO |
|
Analog Inpit (AI) |
0(4)-20mA, 0(1)-5V |
|
Analog Output (AO) |
0(4)-20mA, 0(1)-5V |
| OPTIONAL |
Ethernet |
10M/100M Modbus TCP,HTTP |
| COMMUNICATIONS |
|
Web page Email |
|
Profibus-DP |
Profibus-DP/VO |
| |
|
|
|
|
|
|
|
|
Module Data sheet I/O MODULE OPTION
Module Data |
| Module Name |
Price |
Digital Input |
Power
Supply |
Digital
Output
|
Relay Output |
Analog Input |
Analog Output |
| AXM101 |
$75.00 |
6 |
1 |
|
2 |
|
|
| AXM102 |
$80.00 |
4 |
|
2 |
|
|
2 |
| AXM103 |
$90.00 |
4 |
|
|
2 |
2 |
|
| COMMUNICATION MODULE OPTIONS |
| Module Name |
Specifications |
|
|
| AXM-NET |
10M/ 100M Self Adaptable RJ45 jack
Ethernet Module Data |
|
$135.00 |
Modbus TCP/IP Protocol |
|
|
|
| |
HTTP Web page Browse |
|
|
|
|
Email sending on time internal or event. |
|
|
| PROFIBUS |
Profibus-DP/VO Input Byte typical 32byte |
|
|
| $145.00 |
Output Byte typical 32 byte ENS0170 vol 2 compliance |
| |
Profibus slave mode baud rate self- adaptable up to 12 Meg. |
|

|