Switchboard 3-Phase Power Meter.
3-phase amps, volts, Watt, displayed simultaneously.
 
Field configurable multiple parameter display combinations. Ideal choice
for replacement of failed analog meters because it mounts in ANSI 4.5"
or DIN 96mm cut outs. Modbus communication option. Ships in a few days.
Solves so many monitoring problems with a price range of $320-370.00.
                 Place the meter in a DIN or Round cutout.
 
 
     Acuvim Brochure
 
Acuvim-CL may be used as a data gathering device for an intelligent Power Distribution System or a Plant Automation System. All monitoring data is available via digital RS485 communication port running Modbus RTU Protocol. Modicon Modbus Map.
 
Power system quality is important with increasing use of electronic loads such as computers, ballasts or variable frequency drives. With the Acuvim-L power analysis option, any phase current or voltage can be displayed and the harmonic content calculated.

By knowing the harmonic distribution, action can be taken to
prevent overheated transformers, motors, capacitors, neutral
wires and nuisance breaker trips. Redistribution of the system
loading can also be determined.
Choose the model number via needed parameters.
Offers improved  monitoring and controlling of power distribution system. The electric power parameters available on the ultra-compact Acuvim-L are:
 True-RMS measuring parameter, 4-quadrant Energy
 Power Quality Analysis, Clear LCD screen,Bright Orange Back light.
Acuvim-AL   $320.00   Standard
Acuvim-BL   $340.00   Digital Relay Output
Acuvim-CL   $370.00   RS485 Modbus Communication
Function  Parameter AL BL CL
         
Phase Voltage VL-N, 1, 2, 3 V V V
REAL TIME Line Voltage V L-L, 1-2, 2-3, 3-1 V V V
METERING Current  I1, 2, 3,L-N V V V
Power P1, 2, 3, sum V V V
Reactive Power Q1, 2, 3, sum V V V
Apparent Power Ssum V V V
Power Factor PF1, PF2, PF3, V V V
Load Nature L/C/R L/C/R V V V
         
ENERGY Ep_iimp, p_exp, V V V
ENERGY & REACTIVE ENERGY  Eq_imp, q_exp V V V
DEMAND CURRENT DEMAND Dmd_I1,DDmd_I2 md_II3 V V V
POWER DEMAND Dmd_Psum, md_QQsum V V V
         
Voltage Unbalance U_unbl V V V
POWER Current Unbalance  I_unbl V V V
QUALITY Voltage THD THD_V1, THD_V2, THD_V3, V V V
Current THD THD_I1, THD_I2, THD_I3 V V V
Individual Harmonics 2 nd 15 th (Current/Voltage) V V V
         
Max Current Demand Dmd_I1, I2, I3, max Dmd V V V
Max Power Demand Dmd, Psum, Qsum_max V V V
STATISTICS Max and Min  Voltage   V V V
Max and Min Current   V V V
         
HOUR Running Hour Hour V V V
I/O Energy Pulse Output     V  
Alarm Output     V  
COMMUNICATION RS-4485 MODBUS ®-RTU Protocol     V
         

Acuvim-L Standard Features:

  1. Metering
  2. Voltage V1, V2, V3, V12, V23, V31
  3. Current I1, I2, I3, In
  4. Power P1, P2, P3, Psum
  5. Reactive Power Q1, Q2, Q3, Qsum
  6. Apparent Power Ssum
  7. Frequency F
  8. Power Factor PF1, PF2, PF3, PF
  9. Energy Ep_imp, Ep_exp
  10. Reactive Energy Eq_imp, Eq_exp
  11. Power Quality
  12. Voltage Harmonics 2nd to 15th and THD
  13. Current Harmonics 2nd to 15st and THD
  14. Voltage Imbalance Factor U_unbl
  15. Current Imbalance Factor I_unbl
  16. Max/Min Statistics with Time Stamps
  17. Running Hour

Options Input/Output Power Analysis

Alarm

bulletOne (1) alarm parameter may be set within a specified time interval.
bulletIf indicated parameter is over or    under its setting limit and persists
bulletover the specified time interval, the event will be recorded with time
bulletstamps and trigger the Alarm DO output. The indicated parameter can
bulletbe selected from any of the 31 parameters available.

Pulse Output option

bulletTwo Digital outputs can be configured as pulse output for kWh and kVarh.
bulletThe pulse rate and width can be set.

Communication

bulletRS485, Industry standard Modbus RTU protocol

 

 

 

 

 

 

 

 

 

 

 

 

\

 

 

Hit Counter